11.3. Replacement of liquid in the automatic transmission

If replacement of liquid in the hydrotransformer is made, also replace liquid in the transmission. If replacement of liquid in the hydrotransformer is not made, replace liquid in the transmission as follows.

 PERFORMANCE ORDER

  1. Disconnect a hose which connects the transmission and the oil heater (from a radiator). Turn out a drain stopper from the basis of a case of the transmission and merge liquid.
  2. Establish a drain stopper with laying and tighten the moment given in the specification. Inhaling moment: 32 N • m.
  3. Fill in necessary amount of the required liquid.

Stop liquid filling if the required quantity cannot be filled in in the transmission.

  1. If the bigger amount of transmission liquid was filled in repeat the procedure according to a step 1.
  2. Connect a hose which was disconnected in a step (1) and reliably insert the probe for measurement of level.
  3. Start the engine and leave it to work within 1–2 minutes in the idling mode.
  4. At the working engine move the selector lever from situation "N" to all provisions and back to situation "N".
  5. Make a trip before warming up of the transmission up to the temperature of 70-80 °C. Park the car on a plain horizontal surface. Check the liquid level which has to be between tags of "HOT". If necessary, add necessary amount of the required liquid.
  1. Reliably insert the probe for measurement of level of transmission liquid.