6.2. Valve of ventilation of a case
Removal
|
- Disconnect a hose from the valve of ventilation of a case. Remove the valve from a cover of a head of cylinders and connect it to a hose of ventilation of a case.
- Launch the engine at an idling frequency, a finger close an opening of the valve and be convinced that the depression created in an inlet collector is felt.
|
|
The plunger of the valve of ventilation of a case will not move back and forth. |
|
- If depression is not felt, clear the valve and a hose of ventilation of a case or replace them.
|
|
Check
|
|
- Remove the valve of ventilation of a case.
|
- For check of movement of a plunger insert a thin steel core from a carving part of the valve.
- . If the plunger does not move, so the valve is littered and, it needs to be cleared or replaced.
|
|
Installation
Install the valve of ventilation of a case and tighten it the required moment. Inhaling moment: 8–12 N • m.