18.4. Check of power failure on the wire connecting the rechargeable battery to the generator

This check allows to define reliability of connection of the B plug of the generator with positive () the plug of the rechargeable battery.

Preparation for check

 PERFORMANCE ORDER

  1. Include ignition.

For an exception of further problems at connection of the generator, be convinced that in the course of check did not damage two clips or their connections.

  1. Connect the digital voltmeter to the B plug of the generator and to positive () the plug of the rechargeable battery.

Check condition

Start the engine, include headlights, the fan of a heater and other consumers of electric energy and read indications on the voltmeter.

Result of check

 PERFORMANCE ORDER

  1. The voltmeter has to show tension of 0,3 Century.
  2. If tension more than 0,3 In, so wire has damages or it is unreliably connected to plugs of the generator and the rechargeable battery.
    For check of a wire connect the B plug and the positive plug of the rechargeable battery an additional wire to a fusible insert.
    Check reliability of connection of a wire to plugs, and also be convinced that isolation of a wire is not melted from its overheat.
  3. In conclusion, switch off everything consumers of electric energy and stop the engine.